The XCR offer is a range of limit switches designed for hoisting and material handling applications. This product is a complete switch with a metal stay put head. The operator is made of 2 metal crossed rods of 200mm long. The maximum displacement is 90° in each position.
Range of product | OsiSense XC |
---|---|
Series name | Special format |
Product or component type | Limit switch |
Product specific application | For hoisting and mechanical handling applications |
Device short name | XCR |
Sensor design | – |
body type | Fixed |
Head type | Rotary head |
Material | Metal |
Fixing mode | By the body |
Movement of operating head | Rotary |
Type of operator | Stay put crossed rods lever metal square rod 6 mm |
Type of approach | Lateral approach, 2 directions |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.5…2 x 2.5 mm² |
Number of poles | 4 |
Contacts type and composition | 2 x (1 NC + 1 NO) |
Contact operation | Slow-break, break before make |
Contact block per direction [control circuit] | 1 per direction |
Positive opening | With |
Body material | Zinc alloy |
---|---|
Switch actuation | By any moving part |
Cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm conforming to NF C 68-300 |
Contacts insulation form | Zb |
Number of steps | 1 |
Positive opening minimum torque | 0.7 N.m |
Minimum torque for tripping | 0.6 N.m |
Minimum actuation speed | 6 m/min |
Maximum actuation speed | 1.5 m/s |
Maximum displacement angle | -90 ° 90 ° |
Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
[Ui] rated insulation voltage | 300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) conforming to VDE 0110 300 V conforming to CSA C22.2 No 14 |
Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 |
Short-circuit protection | 10 A cartridge fuse, type gG |
Electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Mechanical durability | 10000000 cycles |
Width | 85 mm |
Height | 95 mm |
Depth | 75 mm |
Net weight | 1.135 kg |
Terminals description ISO n°1 | (13-14)NO (21-22)NC |
Shock resistance | 68 gn conforming to IEC 60068-2-27 |
---|---|
Vibration resistance | 9 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP65 conforming to IEC 60529 |
Overvoltage category | Class I conforming to IEC 61140 Class I conforming to NF C 20-030 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…70 °C |
Protective treatment | TC |
Product certifications | CSA CCC |
Standards | NF C 79-130 EN 60947-5-1 IEC 60947-5-1 IEC 60204-1 EN 60204-1 CSA C22.2 No 14 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 8.0 cm |
Package 1 Width | 10.5 cm |
Package 1 Length | 20.5 cm |
Package 1 Weight | 1.073 kg |