Steute ES 98 SR Conveyor Belt Switch
- Metal enclosure
- 2 contacts
- Design to EN 50041
- Wiring compartment
- Adjustable-length rod lever with nylon roller
- Belt alignment lever adjustable in 13° steps using a self-locking mechanism
- For light- and medium-heavy applications
- Ex version available
Technical data
Applied standards | EN ISO 13849-1, EN 60947-5-1 |
---|---|
Enclosure | aluminium die-cast, powder-coated |
Degree of protection | IP 67 to IEC/EN 60529 |
B10d (10 % load) | 2 million |
TM | max. 20 years |
Contact material | silver |
Switching system | slow action |
Switching elements | 1 NC/1 NO, 2 NC or 1 NC/1 NO contact with contact overlapping, type Zb |
Connection | screw connection terminals |
Cable cross-section | max. 2.5 mm² (incl. conductor ferrules) |
Cable entry | 1 x M20 x 1.5 |
Rated impulse withstand voltage Uimp | 4 kV |
---|---|
Rated insulation voltage Ui | 250 V |
Conventional thermal current Ithe | 6 A |
Rated operating current/voltage Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
Utilisation category | AC-15; DC-13 |
Short-circuit protection | 6 A gG/gN fuse |
Mechanical life | > 1 million operations |
Operation cycles | max. 1800/h |
Ambient temperature | –20 °C … +60 °C |
Approvals |
ES 98 SR-11 | stock type | 1248307 |
ES 98 SR-02 | 1249635 |
ES 98 SR-11U | stock type | 1249802 |
Application
Range of application
Belt alignment switches are suitable for applications with handling equipment. Here they are installed e.g. at both sides of a conveyor belt in order to monitor the misalignment of the belt.
Belt misalignment, evoked by for example not in the middle of conveyor belt positioned goods or pollution of track idlers and deflection pulleys, can lead without any monitoring measurements to damage, destruction, material covering and dropping.
Design and mode of operation
Belt alignment switches are actuated when the conveyor belt becomes misaligned. Depending on the plant arrangements, this signal can either be used to switch the equipment off or to provide automatic correction of the belt alignment. Thus they should be installed at both sides of the conveyor belt close to the deflection and drive pulleys. In case of very long conveyor systems further belt-alignment switches must be installed. Those are actuated with the misalignment of the conveyor belt. This signal can either switch the system off or start an automatic belt position correction, as well as at the same time generate an optical or acoustic indicating or warning signal.
All belt misalignment switches have positive break NC contacts and those of series ZS also have a mechanical latching. At actuation the NC contacts are opened and latched mechanically. The release can either be carried by push button or key. Thus an unintentional, automatic restart of the conveyor belt is prevented.
All belt-alignment switches bear the CE mark according to the Low Voltage Directive 2014/35/EU.